MX 1000EP
| | |
---|
MODEL | MX 1000EP | |
Capacity | 1 kVA / 900 W | |
INPUT | | |
Rated voltage | 208 / 220 / 230 / 240 Vac | |
Voltage range | 110 ~ 176 Vac (linear derating between 50% and 100% load); 176 ~ 280 Vac (no derating); 280 ~ 300 Vac (derating 50%) | |
Frequency | 40 ~ 70 Hz (auto-sensing) | |
Power factor | ≥0.99 | |
Bypass voltage range | -25% ~ +15% (settable) | |
Total harmonic distortion (THDi) | ≤ 6% | |
OUTPUT | | |
Voltage | 208 / 220 / 230 / 240 Vac (settable via LCD) | |
Voltage regulation | ± 1% | |
Frequency | 45 ~ 55 Hz or 55 ~ 65 Hz (synchronized range); 50 / 60 Hz ± 0.1 Hz (battery mode) | |
Waveform | Sinusoidal | |
Power factor | 0.9 | |
Total harmonic distortion (THDv) | ≤ 2% (linear load); ≤ 5% (non-linear load) | |
Crest factor | 3:1 | |
Overload | 105% ~ 125% for 1 min, 125% ~ 150% for 30s, > 150% for 300ms | |
BATTERIES | | |
DC voltage | 24 V (S) | 36 V (S) |
Inbuilt battery | 2 x 9 Ah | 3 x 7 Ah |
Charging curren (max.) | 1 A | |
Recharger time | Standard model : 90% capacity restored in 3 hours; Long time model : depend on the capacity of battery | |
SYSTEM | | |
Efficiency | ≥ 90% (Mains mode) | |
| ≥ 85% (Battery mode) | |
| ≥ 95% (ECO mode) | |
Transfer time | Mains mode to battery mode : 0 ms Inverter mode to bypass mode; 4 ms (tupical) | |
Protections | Short-circuit, overload, overtemperature, battery discharge protection and fan testing protection | |
Communications | RS232 (standard), USB / RS485 / dry contacts / SNMP (optional) | |
Display | LCD + LED | |
Standards | EN 62040-1, EN 62040-2, EN 61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2, IEC 62040-2, IEC 6204001 | |
OTHER | | |
Operating temperature | 0℃ ~ 40℃ | |
Storage temperature | -25℃ ~ 55℃ (without batteries) | |
Relative humidity | 0~95% (non-condensing) | |
Altitude | ≤ 1000 m, derating 1 % for each additional 100 m | |
IP rating | IP 20 | |
Noise level at 1m | ≤ 50 dB | |
Dimensions ( W x D x H ) (mm) | 440 x 338 x 88 | 440 x 444 x 88 |
Packaged dimensions ( W x D x H ) (mm) | 545 x 485 x 201 | 545 x 568 x 201 |
Net weight (kg) | 12.3 | 15.8 |
Gross weight (kg) | 14.3 | 18.9 |
MX 1000EPR
| |
---|
MODEL | MX 1000EPR |
Capacity | 1 kVA / 900 W |
INPUT | |
Rated voltage | 208 / 220 / 230 / 240 Vac |
Voltage range | 110 ~ 176 Vac (linear derating between 50% and 100% load); 176 ~ 280 Vac (no derating); 280 ~ 300 Vac (derating 50%) |
Frequency | 40 ~ 70 Hz (auto-sensing) |
Power factor | ≥0.99 |
Bypass voltage range | -25% ~ +15% (settable) |
Total harmonic distortion (THDi) | ≤ 6% |
OUTPUT | |
Voltage | 208 / 220 / 230 / 240 Vac (settable via LCD) |
Voltage regulation | ± 1% |
Frequency | 45 ~ 55 Hz or 55 ~ 65 Hz (synchronized range); 50 / 60 Hz ± 0.1 Hz (battery mode) |
Waveform | Sinusoidal |
Power factor | 0.9 |
Total harmonic distortion (THDv) | ≤ 2% (linear load); ≤ 5% (non-linear load) |
Crest factor | 3:1 |
Overload | 105% ~ 125% for 1 min, 125% ~ 150% for 30s, > 150% for 300ms |
BATTERIES | |
DC voltage | 24 / 36 V (H) |
Inbuilt battery | / |
Charging curren (max.) | 6 A |
Recharger time | Standard model : 90% capacity restored in 3 hours; Long time model : depend on the capacity of battery |
SYSTEM | |
Efficiency | ≥ 90% (Mains mode) |
| ≥ 85% (Battery mode) |
| ≥ 95% (ECO mode) |
Transfer time | Mains mode to battery mode : 0 ms Inverter mode to bypass mode; 4 ms (tupical) |
Protections | Short-circuit, overload, overtemperature, battery discharge protection and fan testing protection |
Communications | RS232 (standard), USB / RS485 / dry contacts / SNMP (optional) |
Display | LCD + LED |
Standards | EN 62040-1, EN 62040-2, EN 61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2, IEC 62040-2, IEC 6204001 |
OTHER | |
Operating temperature | 0℃ ~ 40℃ |
Storage temperature | -25℃ ~ 55℃ (without batteries) |
Relative humidity | 0~95% (non-condensing) |
Altitude | ≤ 1000 m, derating 1 % for each additional 100 m |
IP rating | IP 20 |
Noise level at 1m | ≤ 50 dB |
Dimensions ( W x D x H ) (mm) | 440 x 338 x 88 |
Packaged dimensions ( W x D x H ) (mm) | 545 x 568 x 201 |
Net weight (kg) | 7.6 |
Gross weight (kg) | 11.1 |
MX 2000EP
| | |
---|
MODEL | MX 2000EP | |
Capacity | 2 kVA / 1800 W | |
INPUT | | |
Rated voltage | 208 / 220 / 230 / 240 Vac | |
Voltage range | 110 ~ 176 Vac (linear derating between 50% and 100% load); 176 ~ 280 Vac (no derating); 280 ~ 300 Vac (derating 50%) | |
Frequency | 40 ~ 70 Hz (auto-sensing) | |
Power factor | ≥0.99 | |
Bypass voltage range | -25% ~ +15% (settable) | |
Total harmonic distortion (THDi) | ≤ 6% | |
OUTPUT | | |
Voltage | 208 / 220 / 230 / 240 Vac (settable via LCD) | |
Voltage regulation | ± 1% | |
Frequency | 45 ~ 55 Hz or 55 ~ 65 Hz (synchronized range); 50 / 60 Hz ± 0.1 Hz (battery mode) | |
Waveform | Sinusoidal | |
Power factor | 0.9 | |
Total harmonic distortion (THDv) | ≤ 2% (linear load); ≤ 5% (non-linear load) | |
Crest factor | 3:1 | |
Overload | 105% ~ 125% for 1 min, 125% ~ 150% for 30s, > 150% for 300ms | |
BATTERIES | | |
DC voltage | 24 V (S) | 36 V (S) |
Inbuilt battery | 2 x 9 Ah | 3 x 7 Ah |
Charging curren (max.) | 1 A | |
Recharger time | Standard model : 90% capacity restored in 3 hours; Long time model : depend on the capacity of battery | |
SYSTEM | | |
Efficiency | ≥ 91% (Mains mode) | |
| ≥ 86% (Battery mode) | |
| ≥ 96% (ECO mode) | |
Transfer time | Mains mode to battery mode : 0 ms Inverter mode to bypass mode; 4 ms (tupical) | |
Protections | Short-circuit, overload, overtemperature, battery discharge protection and fan testing protection | |
Communications | RS232 (standard), USB / RS485 / dry contacts / SNMP (optional) | |
Display | LCD + LED | |
Standards | EN 62040-1, EN 62040-2, EN 61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2, IEC 62040-2, IEC 6204001 | |
OTHER | | |
Operating temperature | 0℃ ~ 40℃ | |
Storage temperature | -25℃ ~ 55℃ (without batteries) | |
Relative humidity | 0~95% (non-condensing) | |
Altitude | ≤ 1000 m, derating 1 % for each additional 100 m | |
IP rating | IP 20 | |
Noise level at 1m | ≤ 50 dB | |
Dimensions ( W x D x H ) (mm) | 440 x 528 x 88 | 440 x 728 x 88 |
Packaged dimensions ( W x D x H ) (mm) | 545 x 652 x 201 | 545 x 852 x 201 |
Net weight (kg) | 21.9 | 27.2 |
Gross weight (kg) | 25.5 | 31.3 |
MX 2000EPR
| |
---|
MODEL | MX 2000EPR |
Capacity | 2 kVA / 1800 W |
INPUT | |
Rated voltage | 208 / 220 / 230 / 240 Vac |
Voltage range | 110 ~ 176 Vac (linear derating between 50% and 100% load); 176 ~ 280 Vac (no derating); 280 ~ 300 Vac (derating 50%) |
Frequency | 40 ~ 70 Hz (auto-sensing) |
Power factor | ≥0.99 |
Bypass voltage range | -25% ~ +15% (settable) |
Total harmonic distortion (THDi) | ≤ 6% |
OUTPUT | |
Voltage | 208 / 220 / 230 / 240 Vac (settable via LCD) |
Voltage regulation | ± 1% |
Frequency | 45 ~ 55 Hz or 55 ~ 65 Hz (synchronized range); 50 / 60 Hz ± 0.1 Hz (battery mode) |
Waveform | Sinusoidal |
Power factor | 0.9 |
Total harmonic distortion (THDv) | ≤ 2% (linear load); ≤ 5% (non-linear load) |
Crest factor | 3:1 |
Overload | 105% ~ 125% for 1 min, 125% ~ 150% for 30s, > 150% for 300ms |
BATTERIES | |
DC voltage | 48 / 72 V (H) |
Inbuilt battery | / |
Charging curren (max.) | 6 A |
Recharger time | Standard model : 90% capacity restored in 3 hours; Long time model : depend on the capacity of battery |
SYSTEM | |
Efficiency | ≥ 91% (Mains mode) |
| ≥ 86% (Battery mode) |
| ≥ 96% (ECO mode) |
Transfer time | Mains mode to battery mode : 0 ms Inverter mode to bypass mode; 4 ms (tupical) |
Protections | Short-circuit, overload, overtemperature, battery discharge protection and fan testing protection |
Communications | RS232 (standard), USB / RS485 / dry contacts / SNMP (optional) |
Display | LCD + LED |
Standards | EN 62040-1, EN 62040-2, EN 61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2, IEC 62040-2, IEC 6204001 |
OTHER | |
Operating temperature | 0℃ ~ 40℃ |
Storage temperature | -25℃ ~ 55℃ (without batteries) |
Relative humidity | 0~95% (non-condensing) |
Altitude | ≤ 1000 m, derating 1 % for each additional 100 m |
IP rating | IP 20 |
Noise level at 1m | ≤ 50 dB |
Dimensions ( W x D x H ) (mm) | 440 x 468 x 88 |
Packaged dimensions ( W x D x H ) (mm) | 545 x 592 x 201 |
Net weight (kg) | 9.7 |
Gross weight (kg) | 13.2 |
MX 3000EP
| |
---|
MODEL | MX 3000EP |
Capacity | 3 kVA / 2700 W |
INPUT | |
Rated voltage | 208 / 220 / 230 / 240 Vac |
Voltage range | 110 ~ 176 Vac (linear derating between 50% and 100% load); 176 ~ 280 Vac (no derating); 280 ~ 300 Vac (derating 50%) |
Frequency | 40 ~ 70 Hz (auto-sensing) |
Power factor | ≥0.99 |
Bypass voltage range | -25% ~ +15% (settable) |
Total harmonic distortion (THDi) | ≤ 6% |
OUTPUT | |
Voltage | 208 / 220 / 230 / 240 Vac (settable via LCD) |
Voltage regulation | ± 1% |
Frequency | 45 ~ 55 Hz or 55 ~ 65 Hz (synchronized range); 50 / 60 Hz ± 0.1 Hz (battery mode) |
Waveform | Sinusoidal |
Power factor | 0.9 |
Total harmonic distortion (THDv) | ≤ 2% (linear load); ≤ 5% (non-linear load) |
Crest factor | 3:1 |
Overload | 105% ~ 125% for 1 min, 125% ~ 150% for 30s, > 150% for 300ms |
BATTERIES | |
DC voltage | 72 V (S) |
Inbuilt battery | 6 x 9 Ah |
Charging curren (max.) | 1 A |
Recharger time | Standard model : 90% capacity restored in 3 hours; Long time model : depend on the capacity of battery |
SYSTEM | |
Efficiency | ≥ 92% (Mains mode) |
| ≥ 87% (Battery mode) |
| ≥ 97% (ECO mode) |
Transfer time | Mains mode to battery mode : 0 ms Inverter mode to bypass mode; 4 ms (tupical) |
Protections | Short-circuit, overload, overtemperature, battery discharge protection and fan testing protection |
Communications | RS232 (standard), USB / RS485 / dry contacts / SNMP (optional) |
Display | LCD + LED |
Standards | EN 62040-1, EN 62040-2, EN 61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2, IEC 62040-2, IEC 6204001 |
OTHER | |
Operating temperature | 0℃ ~ 40℃ |
Storage temperature | -25℃ ~ 55℃ (without batteries) |
Relative humidity | 0~95% (non-condensing) |
Altitude | ≤ 1000 m, derating 1 % for each additional 100 m |
IP rating | IP 20 |
Noise level at 1m | ≤ 50 dB |
Dimensions ( W x D x H ) (mm) | 440 x 728 x 88 |
Packaged dimensions ( W x D x H ) (mm) | 545 x 852 x 201 |
Net weight (kg) | 30.6 |
Gross weight (kg) | 34.0 |
MX 3000EPR
| |
---|
MODEL | MX 3000EPR |
Capacity | 3 kVA / 2700 W |
INPUT | |
Rated voltage | 208 / 220 / 230 / 240 Vac |
Voltage range | 110 ~ 176 Vac (linear derating between 50% and 100% load); 176 ~ 280 Vac (no derating); 280 ~ 300 Vac (derating 50%) |
Frequency | 40 ~ 70 Hz (auto-sensing) |
Power factor | ≥0.99 |
Bypass voltage range | -25% ~ +15% (settable) |
Total harmonic distortion (THDi) | ≤ 6% |
OUTPUT | |
Voltage | 208 / 220 / 230 / 240 Vac (settable via LCD) |
Voltage regulation | ± 1% |
Frequency | 45 ~ 55 Hz or 55 ~ 65 Hz (synchronized range); 50 / 60 Hz ± 0.1 Hz (battery mode) |
Waveform | Sinusoidal |
Power factor | 0.9 |
Total harmonic distortion (THDv) | ≤ 2% (linear load); ≤ 5% (non-linear load) |
Crest factor | 3:1 |
Overload | 105% ~ 125% for 1 min, 125% ~ 150% for 30s, > 150% for 300ms |
BATTERIES | |
DC voltage | 72 / 96 V (H) |
Inbuilt battery | / |
Charging curren (max.) | 6 A |
Recharger time | Standard model : 90% capacity restored in 3 hours; Long time model : depend on the capacity of battery |
SYSTEM | |
Efficiency | ≥ 92% (Mains mode) |
| ≥ 87% (Battery mode) |
| ≥ 97% (ECO mode) |
Transfer time | Mains mode to battery mode : 0 ms Inverter mode to bypass mode; 4 ms (tupical) |
Protections | Short-circuit, overload, overtemperature, battery discharge protection and fan testing protection |
Communications | RS232 (standard), USB / RS485 / dry contacts / SNMP (optional) |
Display | LCD + LED |
Standards | EN 62040-1, EN 62040-2, EN 61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2, IEC 62040-2, IEC 6204001 |
OTHER | |
Operating temperature | 0℃ ~ 40℃ |
Storage temperature | -25℃ ~ 55℃ (without batteries) |
Relative humidity | 0~95% (non-condensing) |
Altitude | ≤ 1000 m, derating 1 % for each additional 100 m |
IP rating | IP 20 |
Noise level at 1m | ≤ 50 dB |
Dimensions ( W x D x H ) (mm) | 440 x 468 x 88 |
Packaged dimensions ( W x D x H ) (mm) | 545 x 592 x 201 |
Net weight (kg) | 10.1 |
Gross weight (kg) | 13.6 |